Specifications

Temperature range Adjustable from ambient to +50°C/+122°F
(Option ACC03 increases temperature range from ambient to +60°C/+140°F)
Salt spray fall-out rates Adjustable from 0.5 to 2 ml per 80 cm2 per hour
Wetting mode (Premium chambers only) Adjustable from ambient to +50°C/+122°F
Drying mode (Premium chambers only) Adjustable from ambient to +50°C/+122°F

Ascott Analytical S120ip Closed - Ascott Analytical Global Leaders for Corrosion Test Chambers, Automotive, Aerospace, Manufacturing. 300L Salt Spray Chamber Ascott Analytical - s450is Closed - Ascott Analytical Global Leaders for Corrosion Test Chambers, Automotive, Aerospace, Manufacturing. Ascott Analytical CC100ip - Ascott Analytical Global Leaders for Corrosion Test Chambers, Automotive, Aerospace, Manufacturing. Ascott Analytical CC2000ip Closed - Ascott Analytical Global Leaders for Corrosion Test Chambers, Automotive, Aerospace, Manufacturing.
Standard salt spray chambers S120iS S300iS S450iS S1000iS S1300iS S2000iS S2600iS
Premium salt spray chambers S120iP S300iP S450iP S1000iP S1300iP S2000iP S2600iP
Chamber Capacity 120 Ltrs/
4.2cu ft
300 Ltrs/
10.5 cu ft
450 Ltrs/
15.8cu ft
1000 Ltrs/
35.3cu ft
1300 Ltrs/
49.5cu ft
2000 Ltrs/
70.6cu ft
2600 Ltrs/
91.8cu ft
Mounting Format Bench top Front Opening Floor Standing Floor standing Floor standing Floor standing Floor standing Floor standing
Loading threshold 280mm/11″ 1100mm/43.3″ 800mm/31.5″ 800mm/31.5″ 800mm/31.5″ 800mm/31.5″ 800mm/31.5″
Chamber external dims, max W 1315mm/51.8″ 1450mm/57″ 1660mm/65.4″ 2025mm/80.0″ 2025mm/80.0″ 2885mm/113.6″ 2885mm/113.6″
D 680mm/26.8″ 769mm/30″ 840mm/33.1″ 1145mm/45.0″ 1316mm/51.8″ 1205mm/47.5″ 1316mm/51.8″
H 800mm/31.5″ 2010mm/80″ 1510mm/59.5″ 1720mm/67.5″ 1965mm/77.4″ 1720mm/67.5″ 1965mm/77.4″
Chamber internal dims, max W 715mm/28.2″ 855mm/34″ 1010mm/39.5″ 1300mm/51.2″ 1300mm/51.2″ 2160mm/85.0″ 2160mm/85.0″
D 490mm/19.3″ 601mm/24″ 640mm/25.0″ 980mm/38.5″ 980mm/38.5″ 980mm/38.5″ 980mm/38.5″
H 490mm/19.3″ 711mm/27″ reducing to 407mm/16″ 1140mm/45.0″ 1320mm/52.0″ 1500mm/59.0″ 1320mm/52.0″ 1500mm/59.0″
Salt solution reservoir ext. dims. W n/a 560mm/22″ 425mm/16.0″ Dia 540mm/21.0″ Dia 540mm/21.0″ Dia 540mm/21.0″ Dia 540mm/21.0″ Dia
D n/a 620mm/24″ 425mm/16.0″ Dia 540mm/21.0″ Dia 540mm/21.0″ Dia 540mm/21.0″ Dia 540mm/21.0″ Dia
H n/a 675mm/26″ 630mm/24.0″ 635mm/25.0″ 635mm/25.0″ 635mm/25.0″ 635mm/25.0″
Extra Reservoir capacity? –see optional accessories: ACC59
Sample racks? see optional accessories: ACC16,ACC17,ACC18
Chamber construction Glass reinforced plastic, Polypropylene & ABS parts
Color 9 Standard Colours to choose from
Electricity supply
Standard models
Premium models
1 phase
1 phase
1 phase
1 phase
1 phase
1 phase
1 phase
1 phase
1 phase
1 phase
1 phase
3 phase
1 phase
3 phase
                        Voltage (VAC) and frequency (Hz) dependent on country/region of installation
Water Requirements 
Deionized/distilled for topping up air saturator and making salt solution. Air saturator requires a continuous water connection 2.5-5.0 bar (36-73 psi). If air saturator is topped up manually option ACC66 must be ordered.
Air Requirements  Clean dry & oil free, 4.0 to 6.0 bar (58-87psi) with 240 Ltrs (8.5cu.ft) per minute flow
Exhaust Requirements  3m (10ft) exhaust pipe is provided which should be terminated outside building (See Accessory ACC58)
Drain Requirements  3m (10ft) drain pipe provided which should be terminated into floor level drain (See Accessory ACC58)
Operating environment conditions                                  +18 to +23°C (+64 to 73°F), 85% max RH (non condensing) ambient