Optional testing facility |
SO2 Gas Dosing |
ACC46 |
Comprising of a chamber mounted dispersion tube, through which SO2 gas can be introduced, at a rate determined by the user adjustable control valve, and monitored by a flowmeter. The gas can be switched on and off automatically, at user programmable times. Designed to enable chambers to meet the requirements of ASTM G85 annex 4, and similar tests. Note: the provision of the SO2 gas cylinder and connector are the user’s responsibility and is not included as part of this option. |
- |
- |
xp |
F |
|
|
|
|
|
|
|
External service utilities |
Additional salt solution reservoir
 |
ACC02/80 |
A 80 Litre capacity salt solution reservoir. With a graduated scale in litres, a hinging lid for ease of filling and cleaning and mounted on castors for mobility. External Dimensions w x d x h: 540 x 380 x 560 mm |
A |
|
Additional salt solution reservoir
 |
ACC02/115 |
A 115 Litre capacity salt solution reservoir. With a graduated scale in litres, a hinging lid for ease of filling and cleaning and mounted on castors
for mobility. External Dimensions: w x d x h: 540 x 480 x 560 mm |
A |
|
Additional salt solution reservoir
 |
ACC02/160 |
A 160 Litre (52 US Gal) capacity salt solution reservoir. With a graduated scale in litres, a hinging lid for ease of filling and cleaning and mounted on castors for mobility. External Dimensions: w x d x h: 825 x 480 x 750 mm |
A |
|
Air agitation of salt solution reservoir
 |
ACC96 |
Designed to assist dissolving salt within an Ascott salt solution reservoir to create a thoroughly mixed salt solution. Uses adjustable regulated compressed air supply to a bubbling device that rests on the bottom of the reservoir. Not available for 120 Ltr models. Note: requires connection to own compressed air supply. |
S |
+ |
xp |
F |
|
Waste water trough & pump |
ACC20 |
Where a floor level drain connection is unavailable this option provides a holding tank into which the chamber drain outlet is terminated. When full, waste water is automatically pumped to a remote drain/effluent tank, up to 10m/32ft horizontally & 3m/10ft vertically from the chamber. |
S |
+ |
xp |
F |
|
Trolley |
ACC24 |
Converts the bench standing chamber to floor standing. Mounted on lockable castors. There is space underneath for one additional reservoir (separate option reference ACC02/100). |
S |
+ |
xp |
A |
|
Regenerable cylinder water deionizer system
 |
ACC06/type 2 |
Provides water of suitable purity for topping up a salt spray chamber air saturator, and for making up salt solution. Requires a continuous mains water supply (max 6 bar/90psi). Supplied with conductivity indicator. Must be regenerated or replaced when exhausted. |
S |
+ |
xp |
A |
|
Air compressor |
ACC04/SSC * |
Provides continuous supply of oil free compressed air to enable chamber to function without local compressed air supply. Can be used to back-up a main compressed air supply if fitted with a pressure switch (separate option reference ACC21/SSC).
* Only suitable for 50 Hz supplies, contact us for details regarding 60 Hz supplies. |
S |
+ |
xp |
A |
|
Air compressor pressure switch |
ACC21/SSC |
Pressure switch and components to enable air compressor (separate option ref; ACC04/SSC) to operate as a back-up to a local main compressed air supply. For accessory ACC04/SSC. |
- |
- |
- |
A |
|
Exhaust salt scrubber
 |
ACC92† |
Removes hightly corrosive salt fog from the chamber exhaust where it is not convenient or possible to vent to the outside of the building. Remove salt by condensation and spraying with water.
† Specify as ACC92/120, ACC92/450, ACC92/1000 and ACC92/2000 for 120, 450, 1000 and 2000 Ltrs models respectively. |
S |
+ |
xp |
A |
|
|
|
|
|
|
|
Data measurement & recording |
1 pen chart recorder paper type † |
ACC08/1 |
1 pen, 100mm/4” wide, paper strip chart recorder, coupled to a temperature sensor, for continuously recording the chamber air temperature (°C). |
S |
+ |
xp |
F |
|
2 pen chart recorder paper type † |
ACC08/2 |
2 pen, 100mm/4” wide, paper strip chart recorder, coupled to temperature and humidity sensors, for continuously recording the air temperature (°C) and relative humidity (%RH). |
- |
+ |
xp |
F |
|
2 pen chart recorder paperless type †
 |
ACC40/2 |
2 pen paperless chart recorder, coupled to temperature and humidity sensors, for continuously recording the chamber air temperature (°C) and relative humidity (%RH). Records values electronically on ‘virtual’ chart. Data can be stored on integral floppy disk drive and/or downloaded to a network computer running appropriate software (see option ACC41) via ethernet connector.
† Recorder is free-standing for 120 Ltrs chambers, & chamber mounted for other models. |
- |
+ |
xp |
F |
|
Software for paperless chart recorder ACC40 |
ACC41 |
Software for paperless chart recorder (separate option ACC40). When loaded on a network computer enables monitoring and graphical storage of actual temperature and humidity profiles.
For accessory ACC40/2. |
- |
- |
- |
A |
|
Hand held pH meter |
ACC11 |
Digital pH meter, for measuring the pH of salt solution fallout over range 0-14 pH with a resolution of 0.01 pH. Supplied complete with buffers. |
S |
+ |
xp |
A |
|
Hand held temp & humidity probe
 |
ACC28 |
Precision hand-held thermo-hygrometer for independently checking the chamber temperature and humidity. Special salt resistant measuring probe with 5m/196” cable. Range; -40 to +85°C & 0 to 100%RH. Requires any size entry port (see option ACC10) to access the chamber interior. |
S |
+ |
xp |
A |
|
Re-transmission of temperature & humidity |
ACC36 |
Re-transmission of chamber temp & humidity as 2 x 0-10VDC signals via externally mounted socket. For remote data logging. |
- |
+ |
xp |
F |
|
Temperature data logger |
ACC50 |
A battery powered mini data logger and temperature sensor. Continuously records the chamber air temperature (°C). Logs can be downloaded to a computer running appropriate software (provided). |
S |
+ |
xp |
F |
|
Temperature & humidity data logger |
ACC52 |
As ACC50, but also records humidity (%RH) levels using a combined temperature and humidity sensor. Requires any size entry port (see option ACC10) to access the chamber interior. |
S |
+ |
xp |
F |
|
|
|
|
|
|
|
Remote communications |
Salt solution reservoir low level alarm |
ACC70 |
Operates if the salt solution level falls below requirement for approximately 18 hours testing at 1-2ml/hour fall-out rates. Sounds audible alarm and displays warning message. If reservoir not refilled within 18 hours chamber program will automatically pause/stop. |
S |
+ |
xp |
F |
|
|
|
|
|
|
|
Additional & alternative chamber fittings |
Entry ports
 |
ACC10† |
Sealable chamber entry port through the chamber’s left hand wall (other locations available on request) to enable the connection of external monitoring/driving equipment. |
S |
+ |
xp |
F |
|
|
† Specify as:
ACC10/35 35mm/1.37" diameter
ACC10/70 70mm/2.75" diameter (not available for 120 Ltr chambers)
ACC10/110 110mm/4.33" diameter (not available for 120 Ltr chambers) |
|
|
|
|
|
Slotted type sample racks
 |
ACC16† |
Removable slotted type sample rack for testing panels/coupons. Each slot is 3mm/1/8” wide and angled at 15 degrees from vertical. Such racks are supplied as standard with each new chamber, unless otherwise specified. Wider slots and/or different angles are available on request.
† Specify as: ACC16/120 (24 slots), ACC16/450 (28 slots), & ACC16/1000/2000 (46 slots) for 120, 450 & 1000/2000 Ltrs models respectively. |
S |
+ |
xp |
A |
|
Rod type sample racks
 |
ACC17† |
Removable rod type sample rack for suspending small test samples hung beneath, or for supporting larger test samples placed on top of these racks.
† Specify as: ACC17/120, ACC17/450, & ACC17/1000/2000 for 120, 450 & 1000/2000 Ltrs models respectively. |
S |
+ |
xp |
A |
|
Spiked type sample racks
 |
ACC18† |
Removable spiked type sample rack for suspending test samples from the 10mm/0.4" diameter x 55mm/2" long spikes, equally spaced, and protruding from opposite sides.
† Specify as: ACC18/120 (9 spikes), ACC18/450 (12 spikes), & ACC18/1000/2000 (18 spikes) for 120, 450 & 1000/2000 Ltrs models respectively. |
S |
+ |
xp |
A |
|
Racks for radiators
 |
ACC84 |
Support racking for different sizes of vehicle radiator. Attachment points allow radiator to be positioned at various angles. Several radiators may be accommodated if the inclination angle is shallow. 2000 Ltrs chambers can hold two racks. |
S |
+ |
xp |
A |
|
Racks for brake disks
 |
ACC88 |
Specifically designed to support vehicle brake disks at an angle of 15 degrees from vertical. Each rack supports two disks. The rack locates over two adjacent sample racks as supplied with each new Ascott chamber. |
S |
+ |
xp |
A |
|
Reinforced false floor
 |
ACC19† |
Removable reinforced false floor, providing a horizontal platform over the chamber base for supporting large/heavy test samples.
† Specify as : ACC19/450, ACC19/1000 & ACC19/2000 for 450, 1000 & 2000 Ltrs models respectively. |
S |
+ |
xp |
A |
|
Interior illumination
 |
ACC26 |
Illuminates the chamber interior when a control panel push-button is pressed. |
S |
+ |
xp |
F |
|
Window insulated cover
 |
ACC82† |
Comprises of an insulated cover, which is specially shaped to match the window aperture. This will reduce the amount of condensation that can form on the inside of the window during testing and will also improve thermal efficiency.
† Specify as : ACC82/120, ACC82/450, ACC82/1000 & ACC82/2000 for 120, 450, 1000 & 2000 Ltrs models respectively. |
S |
+ |
xp |
A |
|
Manual filling air saturator
 |
ACC66 |
Enables air saturator to be manually filled and periodically topped up with water by hand as an alternative to the automatic fill and top up provided as standard. Adds 75mm/3” to external chamber width. |
S |
+ |
xp |
F |
|
Canopy color change


 |
ACC60 |
As standard, and unless otherwise specified, chambers will be fitted with a turquoise colored canopy. By specifying this 'no cost' option, the canopy color can be changed to: (specify color required).
Blue (RAL 5005),
Grey (RAL 7035),
Mauve (RAL 4005),
Red (RAL 3003),
Orange (RAL 1028)
Aqua (RAL 6027) click here to see how the colors look on a chamber |
S |
+ |
xp |
F |
|
|
|
|
|
|
|
Service & spares kits |
1 year consumables spares kit |
ACC12/C |
A kit of consumables sufficient for up to 1 year. Note: 1 consumables spares kit is supplied as standard with every new chamber. Details of kit contents available on request. |
S |
+ |
xp |
A |
|
1 year air compressor service & spares kit for ACC04/SSC |
ACC12/AIR/SSC |
A kit of spare parts for servicing and maintaining the chamber air compressor (optional accessory ref; ACC04/SSC) for up to 1 year. Details of kit contents available on request.
For accessory ACC04/SSC. |
- |
- |
- |
A |
|
1 year service & spares kit for ACC08/1 |
ACC12/REC/1 |
A kit of spare parts for servicing and maintaining the 1 pen paper chart recorder optional accessory for up to 1 year. Details of kit contents available on request.
For accessory ACC08/1. |
- |
- |
- |
A |
|
1 year service & spares kit for ACC08/2 |
ACC12/REC/2 |
A kit of spare parts for servicing and maintaining the 2 pen paper chart recorder optional accessory for up to 1 year. Details of kit contents available on request.
For accessory ACC08/2. |
- |
- |
- |
A |
|
3 year chamber service & spares kit |
ACC12/SSC/3 |
An initial kit of spare parts for servicing and maintaining a chamber for up to 3 years from its first use. Details of kit contents available on request. |
S |
+ |
xp |
A |
|
6 year chamber service & spares kit |
ACC12/SSC/6 |
A comprehensive kit for servicing and maintaining a chamber for up to 6 years from its first use, or its last service. Details of kit contents available on request. |
S |
+ |
xp |
A |